Email Us
Smart Lightning Strikes Counter TDZ-LJQ

Smart Lightning Strikes Counter TDZ-LJQ

With the increasing automation of electronic and electrical systems, electromagnetic pulse interference (such as lightning strikes) can easily cause equipment damage. It is difficult to detect the failure of traditional surge protectors (SPDs) in time, which poses a safety hazard.


This product can monitor the SPD status in real time, including operating conditions, switch status, lightning strike records (number of times, time), etc., and save alarm and lightning strike data. Combined with special software and hardware (such as dynamic ring RTU), an intelligent lightning protection monitoring system can be built to achieve remote data upload and centralized monitoring. It is suitable for decentralized places such as railways, wind power, and airports, effectively reducing protection blind spots and improving equipment safety.


Feature of Smart Lightning Strikes Counter TDZ-LJQ

  • Small size: This product is a rail-mounted instrument that can be easily integrated into lightning protection boxes, lightning protection cabinets, distribution boxes, distribution cabinets, and network cabinets without changing the original product dimensions and layout.

  • Easy to install: All interfaces are plug-in terminals, which can be quickly installed and maintained.

  • Interface types: SPD/SCB remote signal collection, NTC temperature (multiplexing port, when this function is selected, one remote signal port will be missing), PE access status collection, lightning strike counting, ambient temperature and humidity functions, etc.

  • Support local button modification of instrument RS485 address.

  • Communication method: The product is equipped with RS485 interface as standard, which is convenient for data upload and cascade expansion; other communication methods such as Ethernet, Lora, and 4G can also be realized through expansion.

  • Strong anti-interference ability: The serial port is equipped with surge protection circuit, and the acquisition port is designed with photoelectric isolation circuit to ensure that the product is not interfered by surge and electromagnetic waves to the greatest extent.

Specification of Smart Lightning Strikes Counter TDZ-LJQ

Item nameDescription
ModelTDZ-LJQ
Power supply220VAC±10%
power consumption2W
CommunicationRS485Terminal block, standard MODBUS RTU protocol


Baud rate 1200/2400/4800/9600/19200 optional, default 9600; check bit N; data bit 8; stop bit 1


Device address 1~255 optional, default 1
Data acquisition portT01                    Multiplexing porttemperature acquisition(option)Wiring terminal, NTC sensor; anti-shake function to avoid false alarm or frequent alarmFunction: Real-time monitoring of the surface temperature of the lightning arrester (-30℃~160℃).
Alarm: When the set high/low temperature limit is exceeded, the T1 port alarm is triggered and the LED indicator is lit.
Record: Store 65,535 alarm records.
Save detailed data of the last 10 alarms (time, date and extreme temperature value).
Adjustable parameters: Support custom high/low temperature alarm thresholds
Switching data acquisition (Default)Wiring terminal, photoelectric isolation, passive dry contact access; anti-shake function to avoid false alarm or frequent alarmFunction: Monitor the remote signal of the lightning arrester or the switch status of the backup protector (closed = alarm, open = normal).
Alarm: Light up the LED indicator when triggered.
Record: Store 65,535 alarm records.
Save the port number, time and date of the last 10 alarms
T02Switching data acquisition (Default)
Single use port

PE statusCheck the grounding status of the PE line
Indicator light: On: Grounded
Temperature and humidity data acquisitionTemperature-40~85℃
Humidity0~100% RH
Lightning surge data acquisitionCouner functionCan record more than 650 million times; can record the date and time of the latest 9999 surges
Trigger current=200A~100kA
Surge protection typeT1/T2/T3
Surge typeInductor Coil
Power-off data retentionAlarm data is permanently retained after power failure; clock data is retained for more than half a year after power failure
Firmware UpgradeRemote firmware upgrade via serial port
Material/ColorPC+ABS,white,UL94 V-0
Moutning35 mm DIN-rail mounted
Enviroment-40~85℃, 0~95% RH



Installation and Wiring Diagram of Smart Lightning Strikes Counter TDZ-LJQ



Related Products

Leave a Message
contact
Contact Us
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept